BTU Calculator

Find how much heat a room needs in BTUs and watts, the radiator size to buy for a boiler or heat pump, or the air conditioner size for the room — in feet or metres.

Calculate BTUs for a room

What do you want to size?
ft m
ft m
ft m
Walls with the outdoors on the other side
ft² m²
%
For fast warm-up or a north-facing room
°F °C
Bedrooms are often kept cooler
°F °C
A typical cold winter day where you live

Results

How to use the BTU calculator

Heating / radiator estimates how much heat the room loses on a cold day — the output your radiator, heater or vent needs to replace:

  1. Measure the room’s length, width and ceiling height.
  2. Count the outside walls and add up the area of windows and glazed doors in them (width × height of each).
  3. Pick the insulation level closest to your home, and tick whether the floor or ceiling backs onto the ground, a cold loft or the outdoors.
  4. Set the temperature you want indoors and a typical cold winter temperature where you live.
  5. Choose your heating system to see the radiator size to look for in a catalogue.

Air conditioner uses the ENERGY STAR sizing chart for room air conditioners, adjusted for sunshine, people and kitchens.

How the heat loss is calculated

Fabric loss = Σ (U-value × area × ΔT) for walls, windows, floor and roof Air leakage = 0.33 × air changes per hour × room volume × ΔT Heat needed = (fabric loss + air leakage) × (1 + margin) BTU/h = watts × 3.412

ΔT is the difference between the room temperature and the outside temperature. A U-value is how many watts pass through 1 m² of a surface for each degree of difference — the lower, the better insulated. The calculator assumes the rooms next door are heated, so only outside walls count. This is the same simplified steady-state method heating engineers use as a first estimate.

Worked example (US)

A 15 × 12 ft living room with 8 ft ceilings, two outside walls and 30 ft² of windows, in an averagely insulated house with the floor over a crawl space. Heating it to 70 °F when it is 15 °F outside (a 55 °F or 30.6 K difference): walls lose 290 W, windows 239 W, the floor 256 W and air leakage 411 W — 1,196 W in total. With a 10% margin that is 1,315 W, or 4,490 BTU/h (about 25 BTU/h per ft²). A 1,500 W space heater would just cover it.

Worked example (UK)

A 4.5 × 3.5 m living room with 2.4 m ceilings, two outside walls and 3 m² of windows, on the ground floor of an averagely insulated house. Heating it to 21 °C when it is −3 °C outside (ΔT 24): walls 214 W, windows 202 W, floor 189 W and air leakage 299 W — 904 W, or 994 W (3,390 BTU/h) with a 10% margin. With a gas boiler, a radiator rated at about 1,000 W (ΔT50) will do. With a heat pump running at ΔT25, you would need radiators rated at about 2,450 W in total.

U-values used

InsulationWallsWindowsRoof / loftFloorAir changes / hour
Poor – solid walls, single glazing2.14.82.30.71.5
Average – insulated, double glazing0.552.80.350.51
Good – modern, well insulated0.251.40.160.220.5

U-values are in W/m²K. They are typical figures for each kind of house — the real values for your walls and windows may be higher or lower.

Radiator sizes for boilers and heat pumps

Radiator outputs in catalogues are quoted at ΔT50: the water in the radiator averages 50 °C hotter than the room. Run cooler water — as condensing boilers and heat pumps do — and the same radiator gives out less heat, so you need a bigger one.

Heating systemOutput vs. catalogue ratingRadiator rating needed
Boiler (ΔT50)100%1.00 × heat loss
Boiler, low flow temperature (ΔT40)75%1.34 × heat loss
Heat pump (ΔT25)41%2.46 × heat loss

Output falls with (ΔT ÷ 50)1.3, the standard radiator exponent from EN 442. Check the manufacturer’s correction factors for an exact figure.

Air conditioner sizes (ENERGY STAR)

Room area up toCooling capacity
150 ft² (14 m²)5,000 BTU/h
250 ft² (23 m²)6,000 BTU/h
300 ft² (28 m²)7,000 BTU/h
350 ft² (33 m²)8,000 BTU/h
400 ft² (37 m²)9,000 BTU/h
450 ft² (42 m²)10,000 BTU/h
550 ft² (51 m²)12,000 BTU/h
700 ft² (65 m²)14,000 BTU/h
1,000 ft² (93 m²)18,000 BTU/h
1,200 ft² (111 m²)21,000 BTU/h
1,400 ft² (130 m²)23,000 BTU/h
1,500 ft² (139 m²)24,000 BTU/h
2,000 ft² (186 m²)30,000 BTU/h
2,500 ft² (232 m²)34,000 BTU/h

The chart assumes 8 ft (2.4 m) ceilings. An oversized air conditioner cools the room quickly but switches off before it removes humidity, so pick the size closest to the result rather than going much bigger.

These are estimates for a single room. To size a whole-house boiler, furnace or heat pump, get a room-by-room heat loss calculation (Manual J in the US, or an MCS heat loss survey in the UK). To see what heating will cost to run, use the heating cost calculator.

Frequently asked questions

How many BTUs do I need to heat a room?

It depends on the room’s size, how well it is insulated, how many outside walls and windows it has, and how cold it gets outside. An averagely insulated room typically needs 20–30 BTU per hour for each square foot in a moderate climate, and 40–60 BTU/h per ft² in an older, draughty house or a very cold climate. A 15 × 12 ft living room with two outside walls needs about 4,500 BTU/h on a 15 °F day.

What size radiator do I need for my room?

Work out the room’s heat loss in watts, then choose a radiator whose ΔT50 output (the figure in the catalogue) at least matches it. A 4.5 × 3.5 m living room with two outside walls in an averagely insulated house needs about 1,000 W, or 3,400 BTU/h. If the room has two radiators, their outputs add up.

Why do radiators need to be bigger with a heat pump?

Radiator outputs are quoted at ΔT50 — water about 50 °C hotter than the room, as with a traditional boiler. Heat pumps run most efficiently with cooler water, typically around ΔT25, where a radiator gives only about 41% of its rated output. To deliver the same heat, the radiator needs a ΔT50 rating about 2.5 times the room’s heat loss.

What size air conditioner do I need for a 12 × 15 room?

A 12 × 15 ft room is 180 ft², which falls in ENERGY STAR’s 150–250 ft² band: 6,000 BTU/h. Add 10% if the room gets a lot of sun, take off 10% if it is heavily shaded, add 600 BTU/h for each regular occupant over two, and add 4,000 BTU/h if it is a kitchen.

How many BTUs is a watt or a kilowatt?

1 watt equals 3.412 BTU per hour, so 1 kW = 3,412 BTU/h. A 1,500 W space heater gives about 5,100 BTU/h of heat, and a 2 kW heater about 6,800 BTU/h. To convert BTU/h to watts, divide by 3.412.

Built by Paras Garg and checked by Shivam Sharma and Muskan Gupta. Formulas and figures last reviewed on . Results are estimates: product yields vary, so check manufacturer labels and local building rules before you buy or build. Spotted an error? Tell us.