Insulation Calculator

Find out how much insulation to add to your attic or loft — the extra depth, R-value and volume, plus rolls or bags to buy — to reach US R-value targets or the UK’s recommended 270 mm.

Calculate attic or loft insulation

ft m
ft m
in mm
0 if there is none
ft² m²
At the thickness you are laying — on the pack
%

Results

How to use the insulation calculator

  1. Measure the floor of the attic or loft. Ignore the slope of the roof — insulation sits on the attic floor between and over the joists.
  2. Push a ruler into the existing insulation in several places and note the typical depth and material.
  3. Pick your target: an R-value in US mode, or a depth of mineral wool in UK mode (270 mm is recommended).
  4. Choose the insulation you plan to add. Enter the coverage printed on the pack to see how many rolls or bags to buy.

How it works

Each material has a thermal conductivity (λ). The thinner the material needed for the same resistance, the better it insulates. Resistance adds up layer by layer, so the calculator works out what the existing insulation already provides and how much new material makes up the difference.

Existing R = existing depth ÷ λ Extra R = target R − existing R Extra depth = extra R × λ (of the new material) US R-value = metric R (m²K/W) × 5.68

Worked example (US)

A 40 × 30 ft attic (1,200 ft²) has 3.5 inches of old fiberglass batts — about R-11.5. To reach R-49 you need another R-37.5. With fiberglass rolls at about R-3.3 per inch, that is roughly 11.5 more inches.

Worked example (UK)

A 10 × 8 m loft (80 m²) has 100 mm of mineral wool between the joists. To reach the recommended 270 mm you need a 170 mm layer across the joists — about 14.3 m³ of insulation including 5% for waste.

Common insulation materials

MaterialTypical λ (W/m·K)Approx. R per inch
Fiberglass / mineral wool batts or rolls 0.044 R-3.3
Blown (loose-fill) fiberglass 0.058 R-2.5
Blown cellulose 0.041 R-3.5
Sheep’s wool 0.039 R-3.7
Rigid PIR / polyiso board 0.022 R-6.6

Products vary — use the λ value or R-value printed on your product where you can. Blown insulation settles over time, so installers fill to a slightly greater “installed” depth shown on the bag chart.

Safety tips

  • Wear gloves, long sleeves, goggles and a dust mask when handling mineral wool or blown insulation.
  • Only walk on joists or boards — not on the ceiling between them.
  • Keep vents at the eaves clear, and keep insulation away from flues, chimneys and non-rated recessed lights.
  • If you want to use the loft for storage, raise the floor on loft legs so the insulation isn’t squashed.

Better insulation lowers heating bills — see how much with the heating cost calculator.

Frequently asked questions

How much attic insulation do I need?

ENERGY STAR recommends R-30 to R-49 in the warmest US climate zone, R-38 to R-60 in zones 2–3 and R-49 to R-60 in zones 4–8 — most of the country. R-49 is about 14–16 inches of fiberglass or cellulose.

How thick should loft insulation be in the UK?

The Energy Saving Trust recommends 270 mm of mineral wool loft insulation. Many older homes have just 100 mm between the joists, so a 170 mm layer laid across the joists brings them up to the recommended depth.

Can I add new insulation on top of old insulation?

Yes, as long as the old insulation is dry and free of mould or pests. Lay the new layer at right angles to the joists to cover them and reduce gaps. Unfaced batts or rolls are best for top-ups; never put a vapour retarder between the layers.

What does R-value mean?

R-value measures how well a material resists heat flow — the higher, the better it insulates. US R-values are in imperial units; the metric equivalent (RSI, m²K/W) is the US figure divided by 5.68. R-values of layers add together, which is how this calculator works out the top-up you need.

Do I need to keep the loft ventilated?

Yes. Keep eaves vents and soffit vents clear — use baffles or eaves trays where the insulation meets the roof — so moisture can escape. Do not cover recessed lights unless they are rated for contact with insulation, and keep insulation away from flues and chimneys.

Built by Paras Garg and checked by Shivam Sharma and Muskan Gupta. Formulas and figures last reviewed on . Results are estimates: product yields vary, so check manufacturer labels and local building rules before you buy or build. Spotted an error? Tell us.